Mounting force and push-out force of panel screw:
Item | Size | Force of installation(KN) | Push-out force (N) | Force of installation(KN) | Push-out force (N) |
cold-rolled steel sheet | aluminium sheet | ||||
PF11,PF12,PF21 | M3 | 11.2 | 640 | 6.8 | 350 |
M4 | 20.1 | 700 | 13.5 | 443 | |
M5 | 20.1 | 700 | 13.5 | 443 | |
M6 | 22.5 | 860 | 15.7 | 462 | |
PF41 | M3 | 1.1 | 360 | 1.1 | 360 |
M4 | 1.5 | 800 | 1.5 | 800 | |
M5 | 1.5 | 800 | 1.5 | 800 | |
M6 | 2 | 890 | 2 | 890 | |
PF31 | M3 | 22.2 | 489 | 9.8 | 465 |
PF32 | 22.2 | 1334 | 9.8 | 823 | |
PF31 | M4 | 26.7 | 578 | 12.5 | 489 |
PF32 | 26.7 | 1334 | 12.5 | 890 | |
PF31 | M5 | 35.6 | 712 | 15.6 | 667 |
PF32 | 35.6 | 1890 | 15.6 | 1556 | |
PF32 | M6 | 53.4 | 2002 | 19.1 | 1423 |